Q
Can you show me details of multi-level collection device for wax collection (heated tubes from graphite box to collector also ?)
A
Yes, DMF will offer multi-level collection device for wax collection (heated tubes from graphite box to collector.
-
Q
The hot water temperature regulation/ heater is also included in control unit of furnace or separate ?
A
The hot water temperature regulation is set separately, while the heater is included in control unit of furnace.
-
Q
Min and max negative pressure for Ar dewaxing ?
A
Negative Pressure for Ar Dewaxing Max= 35mbar Min=5mbar
-
Q
Max Ar pressure for sintering with Argon atmosphere (without diffusion pump) ? 1000 mbar pressure OK ?
A
∴Max Ar pressure for sintering with Ar (without diffusion pump) =40mbar ∴1000 mbar pressure is availabe but will increase at least 10% equipment cost.
-
Q
If sintering in Ar atmosphere, all the furnace is also under Ar atmosphere at same pressure ?
A
It can be regarded as the same pressure although the pressure near the vacuum access is a bit lower which can be ignored.
-
Q
Floor footprint / Overall dimensions of furnace ?
A
DMF will offer the layput as per requirment in details.
-
Q
Requirements (cooling water/compressed air....) ?
A
Cooling Water: 0.1~0.25MPa, diameter 2", 6~8M3/h
-
Q
Kualitas Ar yang dibutuhkan?
A
Kemurnian Argon: 99.999%
-
Q
Di sisi pembelian/logistik, dapatkah Anda memberi tahu kami apa Kode HS untuk peralatan tersebut (mungkin lebih dari satu)? Kami ingin informasi ini untuk memeriksa apa saja bea masuk yang mungkin dikenakan untuk mengimpor mesin tersebut.
A
Kode HS (Kode Harmonisasi 10 Digit): 8514109000
-
Q
Bisakah Anda memberi tahu saya tentang prosedur dan tindakan pencegahan saat kita menggunakan gas H2 dengan pemanas? Akan sangat membantu jika Anda memberi tahu kami perbedaannya dengan gas N2.
A
Ya, silakan periksa buku panduannya. Buku panduan ditulis dalam bahasa Inggris dan Mandarin.